For the ultimate method of alerting building occupants of the incidence of an emergency, the Protec Algo-Tec™ 6000PLUS/TSR2 is equipped with an integrated voice enhanced sounder. The talking sounder is capable of delivering synchronised alert and evacuate messages around a building, removing any ambiguity, particularly for anyone unfamiliar with the building alert and evacuation strategy, enabling a more prompt and safe building evacuation.
When combined with the LED beacons and multi-sensor fire detection technology, we are able to provide the ultimate and most innovative fire detection PLUS alarm system for buildings.
The 6000PLUS/TSR2 voice enhanced talking sounder is available with seven voice messages plus ‘bell’ sound in addition to the three fire alarm tones compatible with the Protec range of electronic sounders. All voice messages, bell sound and alarm tones are selectable from the control panel, along with volume adjustment. A loop short circuit isolator is incorporated to enhance the system integrity.
Available in either Red or White body colours, the 6000PLUS/TSR2 has an IP65 rating making the product suitable for mounting internally or externally. An optional deep base allows surface mounted cable to be terminated directly into the sounder.
The 6000PLUS/TSR2 is an ideal addition to the fire alarm system providing a clear spoken message to inform the occupant of a fire alarm condition and is compatible for use with the Protec 6000PLUS sensor range.
Standard Messages
“Attention please, attention please. Fire has been reported in the building, please leave the building immediately by the nearest exit”
“May I have your attention please, an incident has been reported in the building please listen for further instructions”
“Attention, attention. This is an emergency. Please leave the building by the nearest available exit”
“This is a test message, no action is required”
Environment | -10°C to 55ºC (95% RH non condensing) |
Ingress Protection | IP65 |
Weight | 244g |
Loop Powered | Yes |
Loop Standby Load | 0.7mA |
Loop Alarm Load | 6mA (9mA with Bell Sound) |
Loop Voltage | 18 – 28V |
Loop Isolator | Yes |
Sounder Volume | 93dB(A) (High), 75dB(A) (Mid), 65dB(A) (Low)* |
Output Details | Piezo sounder. Sounder tone Voice Message and volume selectable at the control panel |
Construction | ABS Base & Body |
Applicable Standards | Designed to EN54 Part 3 & 17 Compliant to CE and LVD standards |
Device Protocol | Algo-Tec™ 6000PLUS |
Datasheet Clique Aqui